Sign In | Join Free | My fazendomedia.com |
|
Brand Name : AI
Model Number : CPT-1
Certification : ISO
Place of Origin : China
MOQ : 1 Set CT VT Testing Equipment
Price : Negotiable
Payment Terms : T/T, Western Union, L/C
Supply Ability : 1000 sets per month
Delivery Time : 15 days
Packaging Details : CT VT Testing Equipment packed in Plywood case
Power supply : AC220V±10%, 50/60Hz±10%
Display : LCD
Keyword : CT analyzer,VT analyzer
Standard : EC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Measuring range : 0~200V
Current Measurement : 0~10A
Voltage output : 0.1~180V (AC)
Current output : 0.001~5A(RMS)
Testing for current transformer equipment:
Testing for Voltage Transformer equipment
Applications of CT/ VT Testing Equipment:
Specifications:
Item Name | CT and VT Testing Equipment | |
Test standards | IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 | |
Power supply | AC220V±10%, 50/60Hz±10% | |
Voltage output | 0.1~180V (AC) | |
Current output | 0.001~5A(RMS) | |
Power output | 500VA | |
Max. knee voltage measurement | 45KV | |
Current measurement | Range | 0~10A (automatically change range in 0.1/0.4/2/10A) |
Error | <±0.1%+0.01%FS |
Voltage measurement | Range | 0~200V (automatically change range in 1V/10V/70V/200V) | |
Error | < ±0.1%+0.01%FS | ||
Turns ratio measurement Range | 1~35000 1~2000, error<0.05% 2000~5000,error<0.1% 5000~35000,error<0.2% | ||
Phase measurement | error | ±2min | |
resolution | 0.01min | ||
Winding resistance measurement | Range | 0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm) | |
Error | < 0.2%RDG+0.02%FS | ||
Maximum resolution : 0.1mΩ | |||
Temperature measurement | -50~100 Celsius degree; error<3 Celsius degree | ||
CT Secondary burden | Range | 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) | |
Error | <0.2%RDG+0.02%FS | ||
Maximum resolution : 0.001ohm | |||
PT Secondary burden | Error | 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) | |
Maximum | <0.2%RDG+0.02%FS | ||
resolution | 0.1ohm | ||
PT ratio measurement | Range | 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% | |
PT ratio error measurement :Typical error<0.05%, Maximum Error<0.1% | |||
PT phase angle measurement maximum error < 3min | |||
Make evaluation for test results according to selected standards Make word report for test result Make word reports one time for multi-group test records on the PC Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test Compare excitation curves with saved excitation curves in the same window | |||
Memory capacity | >1000 groups test results | ||
Working condition temperature | -10℃~50℃; moist ≤90% |
Spares of CT VT Analyer
![]() |
CT VT Testing Equipment Analzer for Current and Voltage Transformer Test Images |